Camera interfaces
Manta Hardware Installation Guide V4.1.0
51
MANTA output description
MANTA block diagram (also PoE)
Figure 30: MANTA: output block diagram
Caution
MANTA
Max. 20 mA per output
OutVCC 30 V may damage the camera.
OutVCC Resistor value*
5 V1.0 k
at 5 mA minimum required
current draw
12 V2.4 k
24 V4.7 k
5 V 270
at 20 mA maximum allow-
able current draw
12 V 620
24 V 1.2 k
* Resistor required if GPOut1/2 connected to a device with < 5 mA
draw, i.e. high impedance
Figure 31: MANTA: OutVCC and external resistor
externintern
OutVCC
GPOut1
GPOut2
R