Manta Technical Manual V7.2.0
101
Camera interfaces
Manta input block diagram
The inputs can be connected directly to the system for voltages up to 24 V DC.
An external resistor is not necessary.
Manta delay and minimum pulse width
The minimum pulse width for all Manta cameras is:
Test conditions
The input signal was driven with 3.3 V and no external additional series resistor.
Figure 76: Manta input block diagram
Note
For customers who designed their system for Manta cameras
with serial numbers prior to the above mentioned hardware
change:
Use your systems with an external resistor without any
restrictions.
Parameter Value
U
in
(low) 0–1.0 V
U
in
(high) 3–24 V
Current (constant-current source) 3–4 mA
Table 37: Manta input parameters
Figure 77: Manta minimum pulse width
In1
Isolated IO GND
External Internal
In2
180R
180R
I
F
0
t
44 s
6 s 20 kHz