Manta Technical Manual V7.2.0
102
Camera interfaces
Manta output block diagram
Manta delay
The cycle delay for all Manta cameras is:
tpdLH < 3.5 µs and tpdHL < 30 µs
Figure 78: Manta: output block diagram
Caution
• Max. 10 mA per output
• Isolated Out Power 30 V may damage the camera.
Isolated Out Power Resistor value*
5V 1.0k
at 5 mA minimum required
current draw
12 V 2.4 k
24 V 4.7 k
* Resistor required if Out1/2 connected to a device with < 5 mA draw, i.e.
high impedance
Table 38: Manta - Isolated Out Power and external resistor
Note
For this reason, we recommend to trigger on the rising edge.
This guarantees a reaction time that is as fast as possible.
ExternalInternal
Isolated Out Power
Out1
Out2
R
R